Modality Clinical uses Disadvantages Pulsed wave Targeted areas: Measures blood flow velocities through pulmonary veins, mitral valve, and in low flow areas in the heart Cannot measure fast blood flow velocities; limited by Nyquist limit Contin- uous wave High velocities: Measures blood flow velocities through the aorta, aortic valve, stenotic valve lesions, regurgitant valvular jets Cannot identify the location of the peak velocity along the ultrasound scan line Color flow Enhances the recognition of Valvular abnormalities and intracardiac shunts Cannot measure fast blood flow velocities; limited by Nyquist limit M-mode Examines a line of motion over time (monodimensional view of the heart); used to view rapidly moving structures, such as valve leaflets Orientation and interpretation of spatial relationships is difficult; can’t measure blood flow velocity

8

0
MedLecturesMadeEasy
Subscribers
87.4K
Total Post
794
Total Views
3.2M
Avg. Views
24.7K
View Profile
This video was published on 2024-05-13 17:46:02 GMT by @MedLecturesMadeEasy on Youtube. MedLecturesMadeEasy has total 87.4K subscribers on Youtube and has a total of 794 video.This video has received 8 Likes which are lower than the average likes that MedLecturesMadeEasy gets . @MedLecturesMadeEasy receives an average views of 24.7K per video on Youtube.This video has received 0 comments which are lower than the average comments that MedLecturesMadeEasy gets . Overall the views for this video was lower than the average for the profile.